415V 60A C39/C13 42-Port  4-in-1 outlet Smart PDU

The 60A C39/C13 42-Port Smart PDU from ANEN is engineered to deliver maximum efficiency and flexibility for high-density server racks.
Detail
Why ANEN
Application Scenario
Solution
FAQ
Part No EZA060BXN42 Input voltage 200~240VAC/346~415VAC, 3-PHASE, WYE
Output voltage 200~240VAC, SINGLE PHASE Qty of outlet (21) C13/C15, (21) C39, WITH SELF-LOCKING FEATURE. THE C39 OUTLET IS COMPATIBILITY FOR C13, C15, C19 AND C21
Input current 60A Circuit breaker 12 UL489 1P 20A MCB 10kAIC
Dimension(LxWxH) 1825*56*75mm Certification UL/CSA (ETL Mark)
Smart features Metering/Switching Each Outlet HTTP/SNMP/SSH/MODBUS/REDFISH API Outlet type C39 TO C13
Outlet control Smart control/monitoring Rack unit 0U
Input power cord UL 5C/6AWG, 10FT Input plug type IEC 60309 415V/63A 6H IP67 Plug

Product Description

The ANEN 415V 60A C39 42-Port Smart PDU is engineered for high-density ai data center environments where reliable power distribution, real-time monitoring, and flexible outlet management are essential. As a high-performance 415v pdu, it combines three-phase power distribution with intelligent metering and individual outlet switching.


Designed around a 3-phase Wye input of 200–240VAC/346–415VAC, the PDU provides three 60A rated input phases and 200–240VAC single-phase outputs. This configuration supports demanding rack loads while helping data center operators maintain balanced and manageable power distribution.


The 42-outlet configuration includes 21 C13/C15 outlets and 21 C39 outlets. Each C39 outlet uses a self-locking design and accepts C13, C15, C19, and C21 plugs, giving operators greater flexibility when rack equipment changes.


For modern power distribution unit data center applications, visibility is just as important as capacity. The integrated smart meter monitors input current, voltage, power, and kWh, while individual outlet metering provides detailed information for each connected load.

Smart Power Distribution Unit Design

A modern smart power distribution unit needs to do more than deliver electricity. It should provide the data and control functions required for efficient rack-level power management.


The ANEN PDU incorporates intelligent monitoring at both the input and outlet levels. Operators can monitor overall electrical performance while also reviewing the current, voltage, power, and energy consumption of individual outlets.


Ethernet and RS485 communication interfaces support HTTP, SNMP, SSH, and MODBUS protocols. These communication options make the PDU suitable for integration with data center infrastructure management platforms, monitoring systems, and other intelligent facility-management environments.


The smart LCD display adds local visibility. Menu-based control allows technicians to review operating information directly at the rack without relying entirely on a remote management platform.


Individual outlet switching provides another layer of control. Operators can remotely manage the ON/OFF status of each outlet, which can simplify equipment maintenance and reduce unnecessary service visits.

3 Phase PDU for AI Data Center Power Distribution

High-density computing environments place greater demands on rack-level electrical infrastructure. A properly engineered 3 phase pdu helps distribute available capacity across multiple circuits while supporting efficient rack power management.


The 415V input configuration is particularly suitable for data center environments that use three-phase distribution upstream and require 200–240VAC single-phase power at the rack level.


Within an ai data center, rack loads can vary significantly depending on server configuration, accelerator hardware, storage equipment, networking devices, and cooling requirements. The alternating phase arrangement helps provide a clear framework for managing those loads.


The PDU also supports more informed data center power design. Instead of relying only on upstream measurements, facility teams can review consumption at the outlet level and identify changing load conditions inside individual racks.


For operators managing high-density deployments, this visibility can support better decisions around rack capacity, circuit allocation, maintenance, and future expansion.

AI Data Center PDU for High-Density Computing

The growth of AI computing has changed the way operators approach rack-level electrical infrastructure. Modern ai data center pdu solutions need to support higher power density while providing accurate monitoring and convenient control.


This PDU addresses those requirements through its 415V three-phase input, 60A rated phase capacity, 42 flexible outlets, and intelligent metering architecture.


The C39 outlet design provides a practical advantage for mixed equipment environments. Because each C39 outlet supports C13, C15, C19, and C21 plugs, operators do not need to limit rack configurations to a single connector type.


Self-locking outlets also help maintain a secure connection in environments where vibration, cable movement, or frequent service activity may affect conventional connections.


For ai data center deployments, the PDU can therefore serve as a rack-level interface between the facility's electrical infrastructure and the equipment installed inside the cabinet.

HPC PDU and Data Center Power Supply Applications

High-performance computing environments require stable and measurable power delivery. An hpc pdu must support demanding rack loads while giving facility operators sufficient visibility into energy consumption and circuit conditions.


The ANEN 415V 60A Smart PDU is suitable for HPC clusters, AI computing racks, server rooms, networking environments, and other high-density applications.


Its outlet-level metering can help operators identify the power consumption of individual servers or equipment groups. Meanwhile, outlet switching allows authorized personnel to control connected loads when equipment requires maintenance or replacement.


The product also supports broader data center power supply strategies. By combining power delivery, measurement, communication, and switching in one rack-level platform, the PDU helps connect electrical infrastructure with digital monitoring systems.

Power Distribution Unit for Data Center Power Requirements

Modern data center power requirements vary according to rack density, equipment type, redundancy architecture, operating temperature, and future expansion plans.


Selecting a PDU therefore requires more than simply matching voltage and current ratings. Engineers must also consider outlet types, breaker protection, monitoring requirements, communication protocols, cable configuration, and physical cabinet integration.


The ANEN PDU addresses these considerations with a comprehensive rack-level design. Its 42 outlets support multiple connector formats, while 12 UL489 20A single-pole breakers provide branch-circuit protection.


The operating ambient temperature range of 0–60°C also supports demanding data center environments.


For larger projects, ANEN can coordinate the PDU with associated data center power cables, data center power whips, plugs, IEC60309 connectors, racks, and power distribution cabinets. This approach allows customers to develop a more consistent data center power system instead of sourcing every component independently.

Why Choose ANEN for Data Center Power Solutions?

A PDU plays an important role in the overall electrical architecture of a rack. Therefore, choosing a manufacturer with broader power-distribution capabilities can simplify both product selection and project coordination.


ANEN combines PDU manufacturing with connector, cable, and cabinet production. This capability allows us to understand the relationship between rack distribution, connection systems, and upstream electrical infrastructure.


For customers developing new data center power solutions, this integrated approach can reduce coordination between multiple suppliers and provide a clearer path from specification to production.


The result is a practical power distribution platform designed around real application requirements rather than a generic off-the-shelf configuration.

Our Advantages as a PDU Manufacturer

ANEN is a direct factory source for customers looking for a reliable data center power distribution unit manufacturer.


Our manufacturing capabilities cover power connectors, cable assemblies, PDUs, power distribution cabinets, and related electrical products. This broader product range allows us to develop coordinated solutions instead of treating the PDU as a standalone component.

Direct Factory Source

Customers work directly with the manufacturer, allowing technical requirements, production details, customization requests, and quality requirements to move efficiently between engineering and production teams.

OEM and ODM Capabilities

ANEN supports OEM and ODM projects involving electrical specifications, mechanical structures, outlet configurations, cable assemblies, labeling, and appearance.

Quality Assurance

Our production and quality-control processes support consistent manufacturing and inspection. The PDU is available with UL/CSA approval and an ETL Mark, supporting applications that require recognized product certifications.

Complete Data Center Power Solutions

ANEN can supply PDUs together with plugs, cables, power distribution cabinets, racks, connectors, and related assemblies.


This makes ANEN a single-source partner for customers developing integrated data center power solutions.

After-Sales Support

Technical communication does not end when production is completed. ANEN provides after-sales support for product application, installation-related questions, troubleshooting, and project follow-up.



Data Center Power Distribution Unit Applications

The ANEN 415V 60A C39 42-Port Smart PDU is designed for applications where reliable power distribution and intelligent monitoring are important.


Typical applications include:

AI Data Centers

High-density AI server racks can benefit from outlet-level metering and remote switching. The flexible C39 outlet architecture also accommodates different server and accelerator power connections.

HPC Facilities

HPC clusters often require substantial rack-level power capacity and detailed energy monitoring. The PDU supports both requirements within a single intelligent distribution platform.

Enterprise Data Centers

Enterprise facilities can use intelligent rack PDUs to monitor equipment consumption, improve operational visibility, and support structured maintenance processes.

Cloud Computing Infrastructure

Cloud and colocation environments can use outlet-level metering to improve rack-level power visibility and support more detailed infrastructure management.

Telecom and Network Rooms

The flexible outlet configuration makes the PDU suitable for telecommunications and networking environments where different equipment may share a cabinet.

Data Center Power Distribution Solutions from ANEN

ANEN approaches data center power distribution as a complete system rather than an isolated product.


A rack-level PDU must work correctly with upstream distribution equipment, cables, connectors, cabinets, and monitoring infrastructure. Consequently, compatibility between components plays an important role in overall project performance.


ANEN can provide coordinated solutions covering:

  • Smart and basic PDUs

  • High-current industrial plugs and connectors

  • Data center power cables

  • Data center power whips

  • Power distribution cabinets

  • Server racks

  • Rack power accessories

  • Customized cable assemblies

For projects with specific electrical or mechanical requirements, ANEN can also discuss customized outlet configurations, cable lengths, connector combinations, cabinet integration, labeling, communication requirements, and exterior finishes.


The standard enclosure uses RAL9005 powder coating. Custom colors are available for projects that require specific branding or cabinet-matching requirements.


FAQ About the 415V 60A C39 Smart PDU

Q:What is a 415V PDU?

A:415V PDU is a power distribution unit designed to receive three-phase power at a nominal 415V level and distribute electrical power to connected equipment. This ANEN model accepts 346–415VAC three-phase Wye input and provides 200–240VAC single-phase outputs.


Q:How many outlets does this PDU have?

A:The PDU provides 42 outlets: 21 C13/C15 outlets and 21 self-locking C39 outlets.


Q:What plugs are compatible with the C39 outlets?

A:The C39 outlets are compatible with C13, C15, C19, and C21 plugs. This design provides greater flexibility for mixed server and IT equipment configurations.


Q: Does the PDU support outlet-level monitoring?

A:Yes. Each outlet can be monitored for current, voltage, power, and kWh.


Q: Can individual outlets be switched ON or OFF?

A:Yes. Individual outlet switching allows operators to control the ON/OFF status of connected equipment.


Q: Which communication protocols does the smart PDU support?

A:The smart meter supports Ethernet and RS485 interfaces, together with HTTP, SNMP, SSH, and MODBUS protocols.


Q: Does the PDU have a local display?

A:Yes. A smart LCD display with menu control provides local monitoring and access to operating information.


Q: What circuit breakers does the PDU use?

A:The unit uses 12 single-pole 20A circuit breakers with UL489 and 10kA specifications.


Q: Can ANEN customize the PDU?

A:Yes. ANEN supports OEM and ODM customization. Options may include mechanical dimensions, outlet configuration, cable assemblies, labeling, communication requirements, and enclosure color.


Q: Can ANEN provide cables and other data center equipment?

A:Yes. ANEN provides comprehensive solutions covering PDUs, plugs, cables, power distribution cabinets, racks, connectors, and related power-distribution products.


Q: What is the operating temperature range?

A:The PDU is designed for an operating ambient temperature range of 0–60°C.


Q: What certifications does the PDU have?

A:The product is available with UL/CSA approval and an ETL Mark, supporting projects that require recognized safety and compliance certifications.

Related Products
Leave Your Message
Name
*
Company
*
Whatsapp
*
Email
*
Message
*
Send

NEWS INFORMATION

As industrial equipment, data centers, and high-performance computing facilities demand more electrical power, reliable power connections have become increasingly important. A suitable 125A industr...
ANEN
2026-10-26
Not every power distribution project can use a standard product. A data center may require a specific combination of C13, C19, and C39 outlets. An electrical equipment manufacturer may need a power...
ANEN
2026-10-22
As artificial intelligence (AI) continues to advance, data centers face growing demands for electrical power, higher rack densities, and more reliable power distribution. AI training clusters, high...
ANEN
2026-10-19
Prev 1 2 3
...
Next
Follow our latest new
HEADQUARTER(China)
+86-189 2553 8006
+86-189 4476 2851
Whatsapp:

No. 20, Lane 2, Nanxin Road,

Humen Town, Dongguan, Guangdong ,

China

sales@anen-power.com
+1-770-409-3178
shawn@anen-power.com
NBC ANEN USA LLC (North America)
support@anen-power.com

Atlanta, GA, USA

NBC Electronic Technological Co., Ltd
TECHNICAL SUPPORT(Worldwide)
CONTACT INFO
USERFUL LINKS
Power Cable