| Part No | EZA125BBG60 | Input voltage | 200~240VAC/346~415VAC, 3-PHASE, WYE | | Output voltage | 200~240VAC, SINGLE PHASE | Qty of outlet | (60) C39 socket, with self-locking, C39 combination socket (C13/C15/C19/C21) | | Input current | 125A | Circuit breaker | 30 UL489 1P 20A MCB 10kAIC | | Dimension(LxWxH) | 2050*100*80 | Certification | UL/CSA (ETL Mark) | | Smart features | Metering/Switching Each Outlet HTTP/SNMP/SSH/MODBUS/REDFISH API | Outlet type | C39 | | Outlet control | Smart control/monitoring | Rack unit | 0U | | Input power cord | UL 5C/2AWG, 10FT, | Input plug type | IEC 60309 415V/125A 6H IP67 Plug |
415V 125A C39 60-Port Smart PDU for AI Data CentersThe ANEN 415V 125A C39 60-Port Smart PDU is a high-capacity pdu engineered for modern AI and high-density computing environments. Designed around a three-phase Wye input architecture, this smart power distribution unit delivers reliable single-phase power to 60 C39 outlets while providing detailed electrical monitoring and remote outlet control.
With a rated input current of 3 × 125A and an input voltage range of 200–240VAC / 346–415VAC, the unit supports demanding data center power requirements without sacrificing visibility or operational control. Its 60 self-locking C39 outlets accept C13, C15, C19, and C21 connections, giving data center operators greater flexibility when deploying mixed server and IT equipment.
The alternating A/B/C phase sequence uses dark gray, light gray, and white outlet colors to simplify phase identification during installation and maintenance. This practical power distribution unit design helps engineers organize loads more effectively and reduce the risk of phase imbalance.
Beyond basic distribution, the PDU monitors input current, voltage, power, and kWh, while also measuring the same parameters at every outlet. Individual outlet switching provides remote ON/OFF control, allowing operators to manage connected equipment without physically accessing the rack.
Why Choose ANEN?ANEN operates as a direct manufacturer rather than simply acting as a distributor. Our capabilities cover product development, engineering, manufacturing, testing, and quality control.
Direct factory supply gives customers better communication with technical teams and greater flexibility when discussing project requirements. Different data center projects often require different power configurations. ANEN provides OEM and ODM services to support customized PDUs, connectors, cables, cabinets, and related power distribution equipment. Quality AssuranceQuality control extends from component selection through manufacturing and final testing. ANEN applies structured production and inspection processes to maintain consistent product performance.
Our manufacturing capabilities include injection molding, automated assembly, precision metal processing, CNC machining, and cable assembly. UL/ETL and International ComplianceThe 415V 125A C39 Smart PDU carries UL/CSA approval through the ETL Mark. This supports customers who require recognized certification for North American projects.
ANEN also maintains experience with international product standards and certifications across its broader power connector and distribution portfolio. Complete Power Infrastructure SupportA reliable data center power distribution unit is only one part of a complete electrical system. ANEN can support customers with PDUs, plugs, connectors, cables, power whips, distribution cabinets, racks, and other related products.
This integrated approach can simplify sourcing and improve compatibility across the project. After-Sales Technical SupportANEN provides technical assistance throughout the product lifecycle, from specification confirmation and installation guidance to troubleshooting and ongoing support.
Our engineering team can work with customers to review electrical requirements and identify appropriate product configurations for specific applications.
Data Center Power Distribution Unit Applications and Use CasesThe ANEN 415V 125A C39 60-Port Smart PDU is designed for applications where high power density and detailed electrical visibility are priorities. AI servers and GPU clusters can place substantial demands on rack-level infrastructure. The high-current three-phase input, 60 C39 outlets, outlet-level metering, and remote switching make this PDU suitable for AI computing racks. High-Performance ComputingHPC environments require stable and scalable power distribution. Engineers can use the PDU to organize rack power across three phases while monitoring energy consumption at both the input and outlet levels. Enterprise Data CentersEnterprise facilities can use intelligent rack PDUs to improve visibility across IT equipment while supporting maintenance and capacity planning. Colocation FacilitiesColocation providers need accurate power information for operational management and customer reporting. Individual outlet metering helps operators understand consumption across different connected loads. Network and Server RoomsThe 48-port architecture supports dense server and networking deployments where conventional low-capacity PDUs may not provide sufficient outlet count or monitoring capabilities. Edge and High-Density ComputingCompact computing environments with concentrated power demand can benefit from intelligent rack-level distribution and remote management.
Where facilities also require data center uninterruptible power, the PDU can form part of a broader power architecture that includes UPS systems, upstream distribution, transfer equipment, and backup power infrastructure.
Data Center Power Solutions: From Rack Distribution to Complete InfrastructureANEN does not approach rack power as an isolated component. Effective data center power solutions require compatible equipment across the entire electrical path.
The 415V 125A C39 Smart PDU can serve as the rack-level distribution point between upstream electrical infrastructure and IT equipment. Depending on project requirements, ANEN can also provide supporting products such as: This broader product portfolio allows customers to develop a more coordinated data center power system instead of sourcing every component independently.
For projects with specialized voltage, current, outlet, cable, connector, or enclosure requirements, ANEN can also evaluate customized configurations. Data Center Power Design and Customization OptionsEvery facility has different data center power requirements. Rack density, input voltage, connector standards, cable routing, monitoring systems, cabinet dimensions, and local regulations can all influence the final PDU configuration.
ANEN supports OEM and ODM development for customers that require modifications beyond the standard 415V 125A C39 configuration.
Potential customization areas include outlet quantity, outlet configuration, cable and input connection options, enclosure dimensions, labeling, color, monitoring requirements, communication interfaces, and other project-specific details.
The standard RAL9005 powder-coated finish provides a clean professional appearance, while custom colors can support corporate branding or equipment identification systems.
For projects using different connection standards, ANEN can also coordinate compatible IEC plug, cable, connector, and distribution solutions as part of a complete package.
This engineering-oriented approach helps customers align the power distribution unit for data center deployment with the actual electrical architecture rather than forcing the installation to fit a fixed product configuration.
PDU Power Distribution Unit FAQQ:What is the input configuration of this PDU? A:The unit uses a three-phase Wye input with 200–240VAC / 346–415VAC input voltage and a rated input current of 3 × 125A.
Q:What type of outlets does the PDU use? A:The PDU provides 60 self-locking C39 outlets. The C39 socket accepts C13, C15, C19, and C21 compatible connections.
Q:Why are the outlets arranged in three colors? A:The outlets follow an alternating phase sequence and use dark gray for Phase A, light gray for Phase B, and white for Phase C. This visual identification helps engineers manage phase distribution during installation and maintenance.
Q:Does the PDU monitor each outlet? A:Yes. The intelligent monitoring system measures current, voltage, power, and kWh for each outlet, in addition to monitoring the PDU input.
Q:Can individual outlets be switched remotely? A:Yes. Each outlet supports ON/OFF switching, allowing remote power management through the compatible control system.
Q:Which communication protocols does the smart meter support? A:The smart meter provides Ethernet and RS485 interfaces and supports HTTP, SNMP, SSH, and MODBUS protocols.
Q:Does the PDU include circuit breakers? A:Yes. The unit uses 30 × 20A single-pole circuit breakers with UL489 certification and a 10kA interrupting rating.
Q:What operating temperature can the PDU support? A:The specified operating ambient temperature range is 0–60°C.
Q:Can ANEN customize the PDU? A:Yes. ANEN provides OEM and ODM services. Depending on project requirements, customers can discuss outlet configurations, colors, labels, cable assemblies, communication requirements, enclosure specifications, and other customization options with the engineering team.
Q:Can ANEN provide other data center power products? A:Yes. ANEN provides a broader range of data center power cables, data center power whips, PDUs, connectors, plugs, distribution cabinets, racks, and related power distribution products.
|