The ANEN 208V 30A 36-Port C13/C39 Smart PDU is designed to provide reliable, intelligent power distribution for modern data centers, high-performance computing (HPC) facilities, and demanding IT environments. Combining 36 self-locking outlets with individual outlet monitoring and switching, this 208V PDU helps operators manage power more precisely, improve equipment visibility, and simplify rack-level power management.
Designed for a 208VAC three-phase delta input, the unit supports a rated input current of 3 × 30A and delivers 208VAC output. Its outlet configuration includes 18 C13/C15 outlets and 18 C39 outlets. The self-locking design helps keep connected power cords securely in place, reducing the risk of accidental disconnection during equipment installation or maintenance.
Beyond basic power delivery, this smart power distribution unit provides input-level and per-outlet measurements for current, voltage, power, and energy consumption. Operators can also switch individual outlets remotely, making it easier to manage connected equipment without accessing the rack physically.
With Ethernet and RS485 connectivity, multiple communication protocols, and a local LCD interface, the ANEN smart PDU gives data center operators the visibility and control needed for increasingly power-intensive IT infrastructure.
Design
A well-planned power distribution unit design needs to balance electrical capacity, outlet availability, equipment compatibility, and convenient maintenance. ANEN developed this 36-port model to address these requirements in a compact rack-level power distribution solution.
The PDU accepts a 208VAC, three-phase delta input with a rated current of 3 × 30A. It distributes 208VAC power through 36 outlets arranged in an alternating phase sequence. This arrangement helps operators identify and manage phase connections more easily.
For quick visual recognition, the outlets use three distinct colors:
Dark Gray: Phase A
Light Gray: Phase B
White: Phase C
The outlet configuration provides two connection types for different IT equipment requirements:
18 × C13/C15 outlets: Suitable for compatible server, networking, and IT equipment power cords.
18 × C39 outlets: A versatile outlet design compatible with C13, C15, C19, and C21 plugs.
Both outlet types incorporate a self-locking feature to help secure connected power cords. This is particularly useful in high-density racks, where cable movement, equipment servicing, and limited access can increase the risk of loose connections.
For circuit protection, the PDU uses three 20A double-pole circuit breakers rated to UL489 with a 10kA interrupting capacity. This arrangement provides defined protection within the PDU's power distribution configuration.
Power Distribution Unit for Data Centers: Material, Construction, and Customization
The mechanical construction of a rack PDU plays an important role in durability, installation, and long-term operation. ANEN designs its products with consideration for enclosure protection, electrical safety, outlet positioning, cable management, and the installation requirements of different rack environments.
This model uses a powder-coated enclosure with a standard RAL9005 black finish. Customers can request alternative colors to align with rack designs, project specifications, or equipment branding.
The outlet bodies provide the insulation required for the specified outlet configuration, while the conductive contacts and internal electrical components must meet the applicable electrical and certification requirements. Exact enclosure metal, material thickness, insulation resin, and contact material can be confirmed during engineering review according to the selected product configuration.
The unit operates in ambient temperatures from 0°C to 60°C, making it suitable for a range of controlled data center and equipment-room environments.
ANEN also supports customization based on project requirements, including:
Outlet types, quantities, and positioning.
PDU dimensions and mounting arrangements.
Enclosure color and product labeling.
Input cable length and connector configuration.
Communication and monitoring requirements, subject to controller compatibility.
Branding, logos, and OEM/ODM product specifications.
As a PDU manufacturer, ANEN can review customer drawings, electrical requirements, rack layouts, and installation conditions before confirming the final configuration. This approach helps buyers select a power distribution unit for data centers that fits their actual
Request a Quote for the ANEN 208V 30A 36-Port Smart PDU
Looking for a reliable rack PDU for your data center, AI computing facility, or HPC installation? The ANEN 208V 30A 36-Port C13/C39 Smart PDU combines flexible outlet connections, detailed electrical monitoring, and individual outlet switching in one integrated solution.
Contact ANEN with your electrical requirements, rack dimensions, cable specifications, and project quantity. Our engineering and sales teams can help review your requirements and recommend a suitable configuration for your application.